Watlow EZ-ZONE RMC Manual de usuario Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 236
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
Watlow EZ-ZONE
®
RMC Module 54 Chapter 3 Operations Page
RMC Module • Operations Page
Display
Parameter Name
Description
Range Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Probus
Index
Parameter
ID
Data
Type
& Read/
Write
[`o;u2]
[ o.v2]
Special Output Function
(1 to 4)
Output Value 2
View the value of this
function's Output 2.
-1,999.000 to 9,999.000°F or
units
-1,128.000 to 5,537.000°C
- - - - 4982
[offset 80]
0x87
(135)
1 to 4
0xC (12)
- - - - 35012 float
R
No Dis-
play
Special Output Function
(1 to 4)
Error 2
View reported cause for
output malfunction.
None (61)
Open (65)
Shorted (127)
Measurement error (140)
Bad calibration data (139)
Ambient error (9)
RTD error (14)
Fail (32)
Math error (1423)
Not sourced (246)
Stale (1617)
Can't process (1659)
- - - - 4984
[offset 80]
0x87
(135)
1 to 4
0x0D (13)
- - - - 35013 uint
R
[`o;u3]
[ o.v3]
Special Output Function
(1 to 4)
Output Value 3
View the value of this
function's Output 3.
-1,999.000 to 9,999.000°F or
units
-1,128.000 to 5,537.000°C
- - - - 4986
[offset 80]
0x87
(135)
1 to 4
0xE (14)
- - - - 35014 float
R
No Dis-
play
Special Output Function
(1 to 4)
Error 3
View reported cause for
output malfunction.
None (61)
Open (65)
Shorted (127)
Measurement error (140)
Bad calibration data (139)
Ambient error (9)
RTD error (14)
Fail (32)
Math error (1423)
Not sourced (246)
Stale (1617)
Can't process (1659)
- - - - 4988
[offset 80]
0x87
(135)
1 to 4
0x0F (15)
- - - - 35015 uint
R
[`o;u4]
[ o.v4]
Special Output Function
(1 to 4)
Output Value 4
View the value of this
function's Output 4.
-1,999.000 to 9,999.000°F or
units
-1,128.000 to 5,537.000°C
- - - - 4990
[offset 80]
0x87
(135)
1 to 4
0x10 (16)
- - - - 35016 float
R
No Dis-
play
Special Output Function
(1 to 4)
Error 4
View reported cause for
output malfunction.
None (61)
Open (65)
Shorted (127)
Measurement error (140)
Bad calibration data (139)
Ambient error (9)
RTD error (14)
Fail (32)
Math error (1423)
Not sourced (246)
Stale (1617)
Can't process (1659)
- - - - 4992
[offset 80]
0x87
(135)
1 to 4
0x11 (17)
- - - - 35017 uint
R
Note:
Some values will be rounded off to fit in the four-character display. Full values can be
read with other interfaces.
Note:
If there is only one instance of a menu, no submenus will appear.
** These parameters/prompts are available in these menus with firmware revisions 6.0
and above.
R: Read
W: Write
E: EEPROM
S: User Set
Vista de pagina 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 235 236

Comentarios a estos manuales

Sin comentarios