Watlow EZ-ZONE
®
RMC Module • 134 • Chapter 5 Profiling Page
RMC Module • Profile Page
Display
Parameter Name
Description
Range Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Probus
Index
Parameter
ID
Data Type
& Read/
Write
[Ent4]
[Ent4]
Step (1 to 250)
Event 4
Select whether output
programmed as Pro-
file Event Out D is on,
unchanged or off dur-
ing this step.
[`oFF] Off (62)
[Ucgd] Unchanged (1557)
[``on] On (63)
Un-
changed
5472
[offset 100]
0x79
(121)
1 to (250)
0x11 (17)
- - - - 21017 uint
RWE
[Ent5]
[Ent5]
Step (1 to 250)
Event 5
Select whether output
programmed as Pro-
file Event Out E is on,
unchanged or off dur-
ing this step.
[`oFF] Off (62)
[Ucgd] Unchanged (1557)
[``on] On (63)
Un-
changed
5474
[offset 100]
0x79
(121)
1 to (250)
0x12 (18)
- - - - 21018 uint
RWE
[Ent6]
[Ent6]
Step (1 to 250)
Event 6
Select whether output
programmed as Pro-
file Event Out F is on,
unchanged or off dur-
ing this step.
[`oFF] Off (62)
[Ucgd] Unchanged (1557)
[``on] On (63)
Un-
changed
5476
[offset 100]
0x79
(121)
1 to (250)
0x13 (19)
- - - - 21019 uint
RWE
[Ent7]
[Ent7]
Step (1 to 250)
Event 7
Select whether output
programmed as Pro-
file Event Out G is on,
unchanged or off dur-
ing this step.
[`oFF] Off (62)
[Ucgd] Unchanged (1557)
[``on] On (63)
Un-
changed
5478
[offset 100]
0x79
(121)
1 to (250)
0x14 (20)
- - - - 21020 uint
RWE
[Ent8]
[Ent8]
Step (1 to 250)
Event 8
Select whether output
programmed as Pro-
file Event Out H is on,
unchanged or off dur-
ing this step.
[`oFF] Off (62)
[Ucgd] Unchanged (1557)
[``on] On (63)
Un-
changed
5480
[offset 100]
0x79
(121)
1 to (250)
0x15 (21)
- - - - 21021 uint
RWE
[S;typ]
[S.typ]
Subroutine Step (1 to
150)
Step Type
Select a step type.
[UStP] Unused Step (50)
[SoAH] Soak (87)
[W;PE] Wait For Process
or Event (1542)
[CLoc] Wait For Time
(1543)
[Stat] State (1515)
[`End] End (27)
[``ti] Time (143)
[rAtE] Rate (81)
Unused 30440
[offset 86]
0x69
(105)
1 to (150)
1
- - - - 5001 uint
RWE
[C;M1]
[C.M1]
Subroutine Step (1 to
150)
Control Mode Loop 1
Set the control mode
for this loop.
[AUto] Auto (10)
[`oFF] Off (62)
[MAn] Manual (54)
Auto
30442
[offset 86]
0x69
(105)
1 to (150)
2
- - - - 5002 uint
RWE
[C;M2]
[C.M2]
Subroutine Step (1 to
150)
Control Mode Loop 2
Set the control mode
for this loop.
[AUto] Auto (10)
[`oFF] Off (62)
[MAn] Manual (54)
Auto
30444
[offset 86]
0x69
(105)
1 to (150)
3
- - - - 5003 uint
RWE
Note: Some values will be rounded off to fit in the four-character display. Full values
can be read with other interfaces.
If there is only one instance of a menu, no submenus will appear.
R: Read
W: Write
E: EEPROM
S: User Set