Watlow EZ-ZONE
®
RMC Module 206 Chapter 7 Features
Process Value
Wet Bulb/Dry Bulb
Source Function A
Source Instance A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Output Value
Error
Process Value
Differential
Source Function A
Source Instance A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Output Value
Error
Pressure Units
Altitude Units
Barometric Pressure
Cross Over Point
Cross Over Band
Function
Filter
Offset
Pressure Units
Altitude Units
Barometric Pressure
Cross Over Point
Cross Over Band
Function
Filter
Offset
Output Value = Filter [(A - B) + Offset]
Display units follows Source A plus relative
Source B
Output Value = Filter [Calculated Humidity + Offset]
where Source A is the Dry Bulb and Source B is the
Wet Bulb
Note: Wet/Dry bulb temperatures are in degrees F and
pressures are in PSI. Output Value is % relative
humidity. Useful temperature range is 10 to 350F
Process Value
Switch Over
Process Value
Ratio
Output Value = Filter [(A / B) + Offset]
If display units of Source A = Source B, no display
units on output value, else follow Source A
Source Function A
Source Instance A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Function A
Source Instance A
Source Error A
Source Function B
Source Instance B
Source Zone B
Source Error B
Source Function C
Source Instance C
Source Zone C
Source Error C
Source Function D
Source Instance D
Source Zone D
Source Error D
Source Function E
Source Instance E
Source Zone E
Source Error E
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Output Value
Error
Source Value A
Source Value B
Source Value C
Source Value D
Source Value E
Output Value
Error
Pressure Units
Pressure Units
Altitude Units
Altitude Units
Barometric Pressure
Barometric Pressure
Cross Over Point
Cross Over Point
Cross Over Band
Cross Over Band
Function
Function
Filter
Filter
Offset
Offset
If E = OFF, Output Value = Filter [A + Offset]
If E = ON, Output Value = Filter [B + Offset]
Display units follows active source.