Watlow EZ-ZONE
®
RML Module • 32 • Chapter 3 Operations Page
RM Limit Module • Operations Page
Display
Parameter Name
Description
Range Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Probus
Index
Parameter
ID
Data
Type
& Read/
Write
[``Ai]
[oPEr]
Analog Input Menu
[``Ain]
[ Ain]
Analog Input (1 to 12)
Process Value
View the process value.
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
- - - - 410
[offset 90]
0x68 (104)
1 to 0x0C
(12)
1
0 4001 float
R
[``pu;f]
[ Pu.F]
Analog Input (1 to 12)
Filtered Process Value
View the process value
when filtering is turned
on..
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
- - - - 452
[offset 90]
0x68 (104)
1 to 0x0C
(12)
0x16 (22)
- - - - 4022 float
R
[`i;Er]
[ i.Er]
Analog Input (1 to 12)
Error Status
View the cause of the most
recent error. If the
[Attn]
message is
[Er;i1]
or
[Er;i2]
, this parameter
will display the cause of
the input error.
[nonE] None (61)
[OPEn] Open (65)
[Shrt] Shorted (127)
[`E;M] Measurement Error
(140)
[E;CAL] Bad Calibration
Data (139)
[Er;Ab] Ambient Error (9)
[E;;Rtd] RTD Error (141)
[FAiL] Fail (32)
[Nsrc] Not Sourced (246)
None 412
[offset 90]
0x68 (104)
1 to 0x0C
(12)
2
1 4002 uint
R
[`i;Ca]
[ i.CA]
Analog Input (1 to 12)
Calibration Offset
Offset the input reading to
compensate for lead wire
resistance or other factors
that cause the input read-
ing to vary from the actual
process value.
-1,999.000 to 9,999.000°F
or units
-1,110.555 to 5,555.000°C
0.0 432
[offset 90]
0x68 (104)
1 to 0x0C
(12)
0xC (12)
2 4012 float
RWES
No Dis-
play
Analog Input (1 to 12)
Clear Latched Input Er-
ror
Clear latched input when
input error condition no
longer exists.
Clear Latch (1221) - - - - 466
[offset 90]
0x68 (104)
1 to 0x0C
(12)
0x1D (29)
- - - - 4029 uint
RW
[`dio]
[oPEr]
Digital Input/Output Menu
[`do;S]
[ do.S]
Digital Output (1 to 8)
Output State
View the state of this out-
put.
[`off] Off (62)
[``on] On (63)
1862
[offset 30]
0x6A (106)
1 to 8
7
90 6007 uint
R
[`di;S]
[ di.S]
Digital Input (1 to 6 and 9)
Input State
View this event input state.
[`off] Off (62)
[``on] On (63)
1870
[offset 30]
0x6A (106)
1 to 6
and 9
0xB (11)
- - - - 6011 uint
R
No Dis-
play
Digital Input (1 to 6 and 9)
Source Value A
View the value of source A
-1,999.000 to 9,999.000°F
or units
-1,128.000 to 5,537.000°C
- - - - 1874
[offset 30]
0x6A (106)
1 to 9
0x0D (13)
- - - - 6013 float
R
Note: Some values will be rounded off to fit in the four-character display. Full values
can be read with other interfaces.
If there is only one instance of a menu, no submenus will appear.
R: Read
W: Write
E: EEPROM
S: User Set