Watlow EZ-ZONE
®
RMS Module 61 Chapter 4 Setup Page
RM Scanner Module Setup Page
Display
Parameter Name
Description
Range Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Probus
Index
Parameter
ID
Data
Type
&
Read/
Write
[`oP;9]
[ op.9]
Linearization (1 to 24)
Output Point 9
Set the value that will be
mapped to input 9.
-1,999.000 to 9,999.000 °F or
units
-1,128.333 to 5537.223 °C
8.0 11390
[offset 70]
0x86 (134)
1 to 0x18
(24)
0x1A (26)
105 34026 float
RWES
[iP;10]
[ip.10]
Linearization (1 to 24)
Input Point 10
Set the value that will be
mapped to output 10.
-1,999.000 to 9,999.000 °F or
units
-1,128.333 to 5537.223 °C
9.0 11372
[offset 70]
0x86 (134)
1 to 0x18
(24)
0x11 (17)
106 34017 float
RWES
[oP;10]
[op.10]
Linearization (1 to 24)
Output Point 10
Set the value that will be
mapped to input 10.
-1,999.000 to 9,999.000 °F or
units
-1,128.333 to 5537.223 °C
9.0 11392
[offset 70]
0x86 (134)
1 to 0x18
(24)
0x1B (27)
107 34027 float
RWES
[`CPE]
[`Set]
Compare Menu
[``Fn]
[ Fn]
Compare (1 to 24)
Function
Set operator that will be
used to compare Source A
to Source B.
[`oFF] Off (62)
[``g;t] Greater Than (1435)
[``L;t] Less Than (1436)
[```E] Equal To (1437)
[``nE] Not Equal To (1438)
[`goE] Greater or Equal
(1439)
[`LoE] Less or Equal (1440)
Off 8236
[offset 40]
0x80 (128)
1 to 0x18
(24)
9
137 28009 uint
RWES
[`toL]
[ toL]
Compare (1 to 24)
Tolerance
If the difference between
Source A and Source B is
less than this value the two
will appear to be equal.
0 to 9,999.000 0.1 8240
[offset 40]
0x80 (128)
1 to 0x18
(24)
0xB (11)
138 28011 float
RWES
[SFn;A]
[SFn.A]
Compare (1 to 24)
Source Function A
Set the type of function
that will be used for this
source.
[nonE] None (61)
[``Ai] Analog Input (142)
[CUrr] Current (22)
[`C;Pr] Cool Power, Control
Loop (161)
[`h;Pr] Heat Power, Control
Loop (160)
[PWr] Power, Control Loop
(73)
[`Lnr] Linearization (238)
[MAt] Math (240)
[``Pu] Process Value (241)
[`SP;C] Set Point Closed,
Control Loop (242)
[`SP;o] Set Point Open, Con-
trol Loop (243)
[`uAr] Variable (245)
None 8220
[offset 40]
0x80 (128)
1 to 0x18
(24)
1
- - - - 28001 uint
RWES
[`Si;A]
[ Si.A]
Compare (1 to 24)
Source Instance A
Set the instance of the
function selected above.
1 to 250 1 8224
[offset 40]
0x80 (128)
1 to 0x18
(24)
3
- - - - 28003 uint
RWES
Note: Some values will be rounded off to fit in the four-character display.
Full values can be read with other interfaces.
If there is only one instance of a menu, no submenus will appear.
R: Read
W: Write
E: EEPROM
S: User
Set