Watlow EZ-ZONE RM-Scanner-Modul Manual de usuario Pagina 104

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 140
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 103
Watlow EZ-ZONE
®
RMS Module 101 Chapter 6 Features
O
f
f
s
e
t
Units
Input Point 1
Output Point 1
Output Point 2
Output Point 3
Output Point 4
Output Point 5
Output Point 6
Output Point 7
Output Point 8
Output Point 9
Output Point 10
Input Point 2
Input Point 3
Input Point 4
Input Point 5
Input Point 6
Input Point 7
Input Point 8
Input Point 9
Input Point 10
F
u
n
c
t
i
o
n
Source Function A
Source Instance A
Source Zone A
Source Error A
Source Function A
Source Instance A
Source Zone A
Source Error A
Source Function A
Source Instance A
Source Zone A
Source Error A
Linearization - Off
Output Value
Output Value
Output Value
Source AValue
Source AValue
Source AValue
Error
Error
Error
O
f
f
s
e
t
Units
Input Point 1
Output Point 1
Output Point 2
Output Point 3
Output Point 4
Output Point 5
Output Point 6
Output Point 7
Output Point 8
Output Point 9
Output Point 10
Input Point 2
Input Point 3
Input Point 4
Input Point 5
Input Point 6
Input Point 7
Input Point 8
Input Point 9
Input Point 10
F
u
n
c
t
i
o
n
Linearization - Interpolated
O
f
f
s
e
t
Units
Input Point 1
Output Point 1
Output Point 2
Output Point 3
Output Point 4
Output Point 5
Output Point 6
Output Point 7
Output Point 8
Output Point 9
Output Point 10
Input Point 2
Input Point 3
Input Point 4
Input Point 5
Input Point 6
Input Point 7
Input Point 8
Input Point 9
Input Point 10
F
u
n
c
t
i
o
n
Linearization - Stepped
Output Function
This function configures and connects physical outputs to
internal functions.
Note:
Digital Outputs not included on these sheets
An error, when read, can indicate any of the following:
None, Open, Shorted, Measurement Error, Bad Cal Data,
Ambient Error, RTD Error, Fail, Math Error, Not Sourced,
Stale
Output
Overview
Instances - 0 to 10 per RMS
Output Value
Error
Output Low Power Scale
Output Time Base
Output Control
Output High Power Scale
Output Function
Output Function Instance
Output Source Zone
Output Source Error
[o;u] Output Value : On, Off
[Fn] Output Function : Off, Analog Input, Alarm, Cool Power, Heat Power,
Compare, Counter, Digital I/O. Profile Event Out A to H, Function Key,
Limit
Logic, Linearization, Math, Process Value, Special Function Output 1 to 4,
Timer, Variable,
[o;Ct] Output Control : Fixed Time Base, Variable Time Base
[Fi] Output Function Instance : 1 to 250
[o;Lo] Output Low Power Scale : 0 to 100 %
[o;hi] Output High Power Scale : 0 to 100 %
[o;tb] Output Time Base : 0.1 to 60.0 seconds
[S2] Output Source : 0 to 16Zone
[otPt]
[`SEt]
Output Menu
Setup Page
Linearization Function
An error, when read, can indicate any of the following:
None, Open, Shorted, Measurement Error, Bad Cal Data,
Ambient Error, RTD Error, Fail, Math Error, Not Sourced,
Stale
Linearization
Instances - 24 per RMS
O
f
f
s
e
t
Units
Input Point 1
Output Point 1
Output Point 2
Output Point 3
Output Point 4
Output Point 5
Output Point 6
Output Point 7
Output Point 8
Output Point 9
Output Point 10
Input Point 2
Input Point 3
Input Point 4
Input Point 5
Input Point 6
Input Point 7
Input Point 8
Input Point 9
Input Point 10
F
u
n
c
t
i
o
n
[Su;A] Source A : -1,999.000 to 9,999.000Value
[o;u] Output Value : -1,999.000 to 9,999.000
[Lnr]
[oPEr]
Linearization Menu
Operation Page
[SFn;A] Source Function A : None, Analog Input, Current, Cool Power, Heat Power,
Power, Linearization, Math, Process Value, Set Point , Set Point , VariableClosed Open
[S2;A] Source A : 0 to 16Zone
[Si;A] Source A : 1 to 250Instance
[Fn] Function : Off, Interpolated, Stepped
[oFSt] Offset : -1,999.000 to 9,999.000
[iP;1] Input Point 1 : -1,999.000 to 9,999.000
[iP;2] Input Point 2 : -1,999.000 to 9,999.000
[iP;3] Input Point 3 : -1,999.000 to 9,999.000
[iP;4] Input Point 4 : -1,999.000 to 9,999.000
[iP;5] Input Point 5 : -1,999.000 to 9,999.000
[iP;6] Input Point 6 : -1,999.000 to 9,999.000
[iP;7] Input Point 7 : -1,999.000 to 9,999.000
[iP;8] Input Point 8 : -1,999.000 to 9,999.000
[iP;9] Input Point 9 : -1,999.000 to 9,999.000
[iP;10] Input Point 10 : -1,999.000 to 9,999.000
[oP;1] Output Point 1 : -1,999.000 to 9,999.000
[oP;2] Output Point 2 : -1,999.000 to 9,999.000
[oP;3] Output Point 3 : -1,999.000 to 9,999.000
[oP;4] Output Point 4 : -1,999.000 to 9,999.000
[oP;5] Output Point 5 : -1,999.000 to 9,999.000
[oP;6] Output Point 6 : -1,999.000 to 9,999.000
[oP;7] Output Point 7 : -1,999.000 to 9,999.000
[oP;8] Output Point 8 : -1,999.000 to 9,999.000
[oP;9] Output Point 9 : -1,999.000 to 9,999.000
[oP;10] Output Point 10 : -1,999.000 to 9,999.000
[Unit] Units : Source, None, Absolute Temperature, Relative Temperature, Power,
Process, Relative Humidity
[Lnr]
[SEt]
Linearization
Setup Page
Source Function A
Source Instance A
Source Zone A
Source Error A
Output Value
Source AValue
Error
Overview
Vista de pagina 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 139 140

Comentarios a estos manuales