Watlow EZ-ZONE
®
RME Module • 69 • Chapter 4 Setup Page
RME Module • Setup Page
Dis-
play
Parameter Name
Description
Range Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Param-
eter
ID
Data
Type
&
Read/
Write
[sfn;B]
[SFn.b]
Math (1 to 8)
Source Function B
Set the type of function
that will be used for this
source.
[nonE] None (61)
[``Ai] Analog Input (142)
[CUrr] Current (22)
[`C;Pr] Cool Power, Control
Loop (161)
[`h;Pr] Heat Power, Control
Loop (160)
[PWr] Power, Control Loop
(73)
[`Lnr] Linearization (238)
[MAt] Math (240)
[``Pu] Process Value (241)
[`SP;C] Set Point Closed,
Control Loop (242)
[`SP;o] Set Point Open,
Control Loop (243)
[`uAr] Variable (245)
None 2182
[offset 70]
0x7D (125)
1 to 8
2
- - - - 25002 uint
RWES
[`si;B]
[ Si.b]
Math (1 to 8)
Source Instance B
Set the instance of the
function selected above.
1 to 250 1 2192
[offset 70]
0x7D (125)
1 to 8
7
- - - - 25007 uint
RWES
[`s2;B]
[ SZ.b]
Math (1 to 8)
Source Zone B
Set the zone of the function
selected above.
0 to 16 0 2202
[offset 70]
0x7D (125)
1 to 8
0x0C (12)
- - - - 25012 uint
RWES
[sfn;C]
[SFn.C]
Math (1 to 8)
Source Function C
Set the type of function
that will be used for this
source.
[nonE] None (61)
[``Ai] Analog Input (142)
[CUrr] Current (22)
[`C;Pr] Cool Power, Control
Loop (161)
[`h;Pr] Heat Power, Control
Loop (160)
[PWr] Power, Control Loop
(73)
[`Lnr] Linearization (238)
[MAt] Math (240)
[``Pu] Process Value (241)
[`SP;C] Set Point Closed,
Control Loop (242)
[`SP;o] Set Point Open,
Control Loop (243)
[`uAr] Variable (245)
None 2184
[offset 70]
0x7D (125)
1 to 8
3
- - - - 25003 uint
RWES
[`si;C]
[ Si.C]
Math (1 to 8)
Source Instance C
Set the instance of the
function selected above.
1 to 250 1 2194
[offset 70]
0x7D (125)
1 to 8
8
- - - - 25008 uint
RWES
[`s2;C]
[ SZ.C]
Math (1 to 8)
Source Zone C
Set the zone of the function
selected above.
0 to 16 0 2204
[offset 70]
0x7D (125)
1 to 8
0x0D (13)
- - - - 25013 uint
RWES
Note:
Some values will be rounded off to fit in the four-character display. Full values can be read
with other interfaces.
Note:
If there is only one instance of a menu, no submenus will appear.
** These parameters/prompts are available in these menus with firmware revisions 6.0 and
above.
R: Read
W: Write
E: EEPROM
S: User Set