Watlow EZ-ZONE
®
RME Module 39 Chapter 4 Setup Page
Chapter 4: Setup Pages
4
[`dio]
[`Set] Digital Input/Output Menu
[```1]
[`dio] Digital Input/Output (1 to 24)
[`dir] Direction
[``Fn] Function
[``Fi] Function Instance
[`S2;A] Source Zone A
[`o;Ct] Control
[`o;tb] Time Base
[`o;Lo] Low Power Scale
[`o;hi] High Power Scale
[`ACt]
[`Set] Action Menu
[```1]
[`ACt] Action (1 to 8)
[``Fn] Function
[``Fi] Function Instance
[SFn;A] Source Function A
[`Si;A] Source Instance A
[`S2;A] Source Zone A
[`LEu] Active Level
[otpt]
[`Set] Output Menu
[```1]
[otpt] Output (1 to 24)
[``Fn] Function
[``Fi] Function Instance
[`S2;A] Source Zone A
[`o;Ct] Control
[`o;tb] Time Base
[`o;Lo] Low Power Scale
[`o;hi] High Power Scale
[otpt] Output 1-3, 7-9, 13-15, 19-21
process
[`o;ty] Type
[``Fn] Function
[``Fi] Function Instance
[`S2;A] Source Zone A
[`S;Lo] Scale Low
[`S;hi] Scale High
[`r;Lo] Range Low
[`r;hi] Range High
[`o;CA] Calibration Offset
[ALM]
[`Set] Alarm Menu
[```1]
[ALM] Alarm (1 to 8)
[`A;ty] Type
[`Sr;A] Source
[`is;A] Source Instance
[`S2;A] Source Zone
[`A;hy] Hysteresis
[`a;Lg] Logic
[`A;SD] Sides
[`A;Lo] Low Set Point **
[`A;hi] High Set Point **
[`a;LA] Latching
[`A;bL] Blocking
[`a;Si] Silencing
[A;dsp] Display
[`A;dL] Delay Time
[a;Clr] Clear Request **
[a;sir] Silence Request **
[`a;st] State **
[CUrr]
[`Set] Current Menu
[```1]
[CUrr] Current 1 to 4
[`C;Sd] Sides
[`C;Ur] Read Enable
[`C;dt] Detection Threshold
[`C;SC] Input Current Scaling
[C;ofs] Heater Current Offset
[`C;Si] Output Source Instance
[`Lnr]
[`Set] Linearization Menu
[```1]
[`Lnr] Linearization (1 to 8)
[``Fn] Function
[SFn;A] Source Function A
[`Si;A] Source Instance A
[`S2;A] Source Zone A
[Unit] Units
[`ip;1] Input Point 1
[`op;1] Output Point 1
[`ip;2] Input Point 2
[`op;2] Output Point 2
[`ip;3] Input Point 3
[`op;3] Output Point 3
[`ip;4] Input Point 4
[`op;4] Output Point 4
[`ip;5] Input Point 5
[`op;5] Output Point 5
[`ip;6] Input Point 6
[`op;6] Output Point 6
[`ip;7] Input Point 7
[`op;7] Output Point 7
[`ip;8] Input Point 8
Setup Page Parameters
To navigate to the Setup Page using the RUI, follow
the steps below:
1. From the Home Page, press both the Up ¿ and
Down ¯ keys for six seconds. [``Ai] will appear
in the upper display and [`Set] will appear in the
lower display.
Note:
If keys are released when [OPEr] is displayed, press
the Infinity Key ˆ or reset key to exit and repeat un-
til [`Set] is displayed.
2. Press the Up ¿ or Down ¯ key to view available
menus.
3. Press the Advance Key
to enter the menu of
choice.
4. If a submenu exists (more than one instance), press
the Up ¿ or Down ¯ key to select and then press
the Advance Key
to enter.
5. Press the Up ¿ or Down ¯ key to move through
available menu prompts.
6. Press the Infinity Key ˆ to move backwards
through the levels: parameter to submenu; submenu
to menu; menu to Home Page.
7. Press and hold the Infinity Key ˆ for two seconds to
return to the Home Page.
On the following pages, top level menus are identified
with a yellow background color.
Note:
Some of these menus and parameters may not appear, depending on the controller's options. See model number
information in the Appendix for more information. If there is only one instance of a menu, no submenus will ap-
pear.
Note:
Some of the listed parameters may not be visible. Parameter visibility is dependent upon controller part number.