Watlow Series 935A Manual de usuario Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 68
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
Table 11 (below) and Table 10 (p. 25) illustrate the Series 935A alarm features.
Table 11 - Alarm Functions
SET
Latching alarm
Silence alarm
With this selection, an alarm
cannot be silenced at the 935A
front panel (unless the alarm
is latched [ [~LAt] = [yes] ],
and the alarm condition
no longer exists).
SET
A value from input Range Low to [`AhI].
A value from [`alo] to input Range High
Alarm Low
Alarm High
An unlatched alarm self-clears
when actual temperature returns
to within the safe area.
At the Range Low value, a , press
displays [`off] and [`ahi] disables.
At the Range High value, a . press
displays [`off] and [`ahi] disables.
[`lat]
[`sIl]
[`alO]
[`ahI]
[``no]
[``no]
[`yes]
[`yes]
A latched alarm requires the
operator to press the ß
key to clear after the actual
temperature returns to within
the safe area.
With this selection, an alarm
can be silenced by pressing the
ß key. [yes] provides automatic
alarm silencing on start up.
Watlow Series 935A Users Manual 27