Application 16 Watlow MiniChef 2000 67
Configuration Mode Quick Reference
These are the functions, parameters and values included in the Configuration Mode for
this application. You must select Application 16 to access them. For directions, see the
Hardware & Software Setup Guide. The Appendix of that guide includes an explanation
of all parameters and values.
Function Parameter Value Your Settings
{Etype} Equipment-Type [appl`] Application Number 1 - 28 16
[a_Loc] Application Number Yes, No
Security Lock
[Sound] Audible Alarm Sound 0 - 5
[preHt] Preheat Temperature Temperature range low to range hi
[melt] Oil Melt Cycle On, Off
[SEtUP] Setup [`Ç_Ï`] Temperature Display Format ºC or ºF
[time] Time Display Format MMM:SS, HH:MM, H:MM:SS
(H=Hours, M=Minutes, S=Seconds)
[Chirp] Key Chirp On, Off
[loc``] Menu Security Lock Yes, No
[tc```] Thermocouple Type J, K (shown as [````H]), E
[rtd``] RTD Curve DIN, JIS
[tconp] WatCurve
TM
Temperature On, Off
Compensation
[Ofst1] Temperature Offset, Channel 1 -99 to 99ºF (-55 to 55ºC)
[tr`lo] Temperature Range Low 0ºF (-18
º
C) for RTD inputs,
32
º
F (0
º
C) for tc inputs to [tr`Hi]
[tr`Hi] Temperature Range High [tr`lo] to 1200ºF (649ºC)
[ready] Preheat Ready Feature Yes, No
[rband] Ready Band 1 to 1200ºF (649ºC)
[Cloc`] Real Time Clock Display Yes, No
[plOSS] Power Loss Menu Resume Yes, No
[al``1] Alarms for channel 1 None, Dev, Proc, Both
[aL`P1] Absolute Process Alarm 1 100 to 1200ºF (38 to 649ºC)
[aLdL1] Low Deviation Alarm 1 -999 to 0ºF (-555 to 0ºC)
[aLdH1] High Deviation Alarm 1 0 to 999ºF (0 to 555ºC)
[tHErl] Thermal [tyPE`] Temperature Control Type PID, On-Off
[HYSt1] Hysteresis 1 1 to 99ºF (1 to 55ºC)
[Pid`U] PID Units SI, US
[tune1] Auto-tuning 1 on, OFF
[ProP1] Proportional Band 1 1 to 999ºF (1 to 555ºC)
[rSEt1] Reset (integral) Gain 1 0.00 to 9.99 repeats/minute
[int`1] Integral Gain 1 0.00 to 99.99 minutes/repeat
[rAtE1] Rate (derivative) Gain 1 0.00 to 9.99 minutes
[dEr`1] Derivative Gain 1 0.00 to 9.99 minutes
[CYcL1] PID Cycle Time 1 1 to 60 seconds
[`diag] WatHelp Used for equipment troubleshooting and testing. Not used when programming. See the Hardware