38 Watlow MINICHEF 2000 Application 13
Program Mode Quick Reference
These are the functions, parameters and values included in the Program Mode for this
application. You must select Application 13 to access them. For menu programming
directions, see the Hardware & Software Setup Guide. The Appendix of that guide
includes a detailed explanation of all parameters and values.
Function Parameter Value Your Settings
[M`__] Menu [Stpt1] Setpoint 1 Temp range low
Numbers 1-6 Temperature of channel 1. to temp range high
[TiNe1] Time 1 Format varies based
Menu run time. on configuration. Setting at 0
invalidates selected menu.
Auto-tuning Note:
Before auto-tuning Application 13, Set Point 1 of Menu 1 must first be set to a value
that is typical of your application. (See Hardware & Software Setup Guide for informa-
tion on programming menus.). Then set [tHerL] / [tunE1] to [```on]. After you
accept [```on],, by pressing “Enter,” the controller will display [`tunE] while auto-
tuning is taking place.
The controller will cancel the auto-tuning process if it cannot be completed in 80 min-
utes. You can cancel the auto-tuning process at any time by pressing either key C or key
D and accepting [``Off], by pressing “Enter,” when it appears.