Watlow Power Supply for MLS300 Manual de usuario

Busca en linea o descarga Manual de usuario para Sensores Watlow Power Supply for MLS300. Watlow Power Supply for MLS300 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 4
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
AC-DC
Specification
5-60 Watts
Rugged Design for Industrial Applications
Up to 89% Efficiency
Wide Adjustment Range
DC OK 24 V Models
DC Standby Versions
Connector Options
Full Power to +60 ˚C
DNR05-60 Series
Input
Input Voltage 90-264 VAC, 120-370 VDC: DNR05/10/18
85-264 VAC, 90-375 VDC: DNR30/60
Input Frequency 47-63 Hz
Inrush Current 5-18 W: 10/18 A at 115/230 VAC
30 W: 20/40 A at 115/230 VAC
60 W: 30/60 A at 115/230 VAC
Power Factor Meets EN61000-3-2 for class A equipment
Earth Leakage Current 0.8 mA max
Output
Output Voltage See tables
Output Voltage Trim See tables
Initial Set Accuracy ±1%
Minimum Load No minimum load required
Start Up Delay <1000 ms
Start Up Rise Time <150 ms
Hold Up Time 5 W: 30/130 ms at 115/230 VAC
10 W: 25/100 ms at 115/230 VAC
18 W: 20/75 ms at 115/230 VAC
30 W: 20/30 ms at 115/230 VAC
60 W: 20/30 ms at 115/230 VAC
Line Regulation
5-18 W
: ±1.0% max
30-60 W: ±0.5% max
Load Regulation
5-18 W
:
±2.0% max
30-60 W: ±0.5% max
Transient Response 300 µs for a 50% load change
Ripple & Noise
50 mV pk-pk, 20 MHz BW
Overvoltage Protection Output clamps at 120-145% Vnom
Overload Protection 105-145%
Shor
t Cir
cuit Pr
otection
5-18 W
: T
rip and r
estar
t (Hiccup mode)
30-60 W: Constant power
Temperature ±0.03%/ºC
Coefficient
x
ppower.com
General
Ef
ficiency
See tables
Isolation 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Switching Frequency 100 KHz typical
Signals DC ON indicator LED Green: All models
DC LOW indicator LED Red:
5-18 W models
DC OK: 24 V 30-60 W models
MTBF 200 kHrs typical per MIL-HDBK-217F
GF, +40 ºC
Environmental
Operating Temperature -10 °C to +70 °C, derate linearly from
+50 °C for 5 & 18 W models, +60 °C for
all other models (See derating curves)
Cooling Convection-cooled
Operating Humidity 20-95% RH, non-condensing
Storage Temperature -25 ºC to +85 ºC
Shock 4 g, 22 ms, X, Y & Z axis
Vibration 1 g, 10 Hz to 500 kHz, along X, Y & Z axis
EMC & Safety
Emissions
EN55022, level B conducted
Har
monic Cur
r
ents
EN61000-3-2, class A
Voltage Flicker EN61000-3-3 amendments 1 & 2
ESD Immunity EN61000-4-2, level 3 Perf Criteria A
Radiated Immunity EN61000-4-3, level 3 Perf Criteria A
EFT/Burst EN61000-4-4, level 3 Perf Criteria A
Sur
ge
EN61000-4-5, level 3 Per
f Criteria A
Dips & Inter
ruptions
EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Per
f Criteria A, B, B
Safety Approvals EN60950-1:2001, UL508,
UL1310 - see note 3 & ratings table,
UL60950-1, cUL60950-1, CE Mark
Vista de pagina 0
1 2 3 4

Indice de contenidos

Pagina 1 - DNR05-60 Series

AC-DCSpecification5-60 Watts• Rugged Design for Industrial Applications• Up to 89% Efficiency• Wide Adjustment Range• DC OK 24 V Models• DC Standby Ve

Pagina 2 - DNR05-60

AC-DCDNR05-60Models and RatingsOutputVoltageOutputVoltage TrimCurrentTypicalEfficiencyModelNumber5 V 4.50-5.75 V 1.000 A 69% DNR05US05(1,3)12 V 10.80-

Pagina 3

AC-DC54.53 (115.0)1.59(40.5)3.60(90.0)AC InputDC OutputON1231234DNR05-60DNR30/60 ConnectionsConn PinDesignationACInput1 Ground2 Neutral3 LineDCOutput1

Pagina 4

09-Oct-07AC-DCStandby VersionsDNR05-60Notes‘*’ at the end of the part number denotes DC standby system.+--DC OKRelayControlRelayCoilBatteryFuseD1LOADD

Comentarios a estos manuales