AC-DC
Specification
5-60 Watts
• Rugged Design for Industrial Applications
• Up to 89% Efficiency
• Wide Adjustment Range
• DC OK 24 V Models
• DC Standby Versions
• Connector Options
• Full Power to +60 ˚C
DNR05-60 Series
Input
Input Voltage • 90-264 VAC, 120-370 VDC: DNR05/10/18
85-264 VAC, 90-375 VDC: DNR30/60
Input Frequency • 47-63 Hz
Inrush Current • 5-18 W: 10/18 A at 115/230 VAC
30 W: 20/40 A at 115/230 VAC
60 W: 30/60 A at 115/230 VAC
Power Factor • Meets EN61000-3-2 for class A equipment
Earth Leakage Current • 0.8 mA max
Output
Output Voltage • See tables
Output Voltage Trim • See tables
Initial Set Accuracy • ±1%
Minimum Load • No minimum load required
Start Up Delay • <1000 ms
Start Up Rise Time • <150 ms
Hold Up Time • 5 W: 30/130 ms at 115/230 VAC
10 W: 25/100 ms at 115/230 VAC
18 W: 20/75 ms at 115/230 VAC
30 W: 20/30 ms at 115/230 VAC
60 W: 20/30 ms at 115/230 VAC
Line Regulation •
5-18 W
: ±1.0% max
30-60 W: ±0.5% max
Load Regulation •
5-18 W
:
±2.0% max
30-60 W: ±0.5% max
Transient Response • 300 µs for a 50% load change
Ripple & Noise •
50 mV pk-pk, 20 MHz BW
Overvoltage Protection • Output clamps at 120-145% Vnom
Overload Protection • 105-145%
Shor
t Cir
cuit Pr
otection
•
5-18 W
: T
rip and r
estar
t (Hiccup mode)
30-60 W: Constant power
Temperature • ±0.03%/ºC
Coefficient
x
ppower.com
General
Ef
ficiency
•
See tables
Isolation • 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Switching Frequency • 100 KHz typical
Signals • DC ON indicator LED Green: All models
DC LOW indicator LED Red:
5-18 W models
DC OK: 24 V 30-60 W models
MTBF • 200 kHrs typical per MIL-HDBK-217F
GF, +40 ºC
Environmental
Operating Temperature • -10 °C to +70 °C, derate linearly from
+50 °C for 5 & 18 W models, +60 °C for
all other models (See derating curves)
Cooling • Convection-cooled
Operating Humidity • 20-95% RH, non-condensing
Storage Temperature • -25 ºC to +85 ºC
Shock • 4 g, 22 ms, X, Y & Z axis
Vibration • 1 g, 10 Hz to 500 kHz, along X, Y & Z axis
EMC & Safety
Emissions •
EN55022, level B conducted
Har
monic Cur
r
ents
•
EN61000-3-2, class A
Voltage Flicker • EN61000-3-3 amendments 1 & 2
ESD Immunity • EN61000-4-2, level 3 Perf Criteria A
Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A
EFT/Burst • EN61000-4-4, level 3 Perf Criteria A
Sur
ge
•
EN61000-4-5, level 3 Per
f Criteria A
Dips & Inter
ruptions
•
EN61000-4-11, 30% 10 ms,
60% 100 ms, 100% 5000 ms
Per
f Criteria A, B, B
Safety Approvals • EN60950-1:2001, UL508,
UL1310 - see note 3 & ratings table,
UL60950-1, cUL60950-1, CE Mark