A.8 WATLOW Series 988LF Users Manual Appendix
Figure A.8-
The Series 988LF Map
NOTE:
This is a complete
listing of all Series
988LF prompts.
Not all prompts will
appear on your
control. They are
dependent on your
configuration and
model number.
Display Loop
(Lower Display)
Press µ to exit
any menu and
reach the Display
Loop at any time.
To Navigate:
Press to return to the
Display Loop from any
location and to advance
through the Display Loop.
Press > or < to move
between the menus.
Press µ to advance
through a menu.
Hold µ while pressing
> to move backwards
through the menus.
Press > or < to
select prompt values.
Fcty
Factory
( )
µ
µ
Test output
(diAg)
Software revision
Serial number
Ambient temperatur
e
Ambient A/D count
(Diagnostics)
Factory ship date
dAtE
SOFt
Sn
AMb
Acnt
gnd
cnt2
ity1
ity2
cnt1
Oty1
Oty2
dISP
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
Input 2 A/D count
Input 1 A/D count
Input 1 module
Input 2 module
Ground A/D count
Output 1 module
Output 2 module
Test displays
tout
( )
( )
Open loop
OPLP ( )
Factory Menus
At the Setup Menu, press > and < another
3 seconds to enter the Factory Menus.
µ
Reset 1
Proportional band 1
Rate 1
Cycle time 1
Proportional band
2
Set point 2
SP2
rE1
rA1
Ct1
Pb2
Pb1
rE2
db
ALO
AUt
L-r
rA2
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
Deadband
Rate 2
Alarm Lo
Auto-tune
Local-remote
Reset 2
AHI
( )
Alarm Hi
CAL
Calibration offset
( )
Ct2
( )
Cycle time 2
(Operation)
Operation
Menu
Press µ to
advance to the
Operation Menu.
Menu Overview
(CAL)
(Calibration)
A 50
t c
A 0H
A 20
A 15
A 00
A380
A 0U
A20A
b 15
b380
A10U
b10U
b 0U
b 4A
b 0U
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
b100
1 4
1 20
1 0
1 10
A 4A
b20A
rSt
A 0U
A100
b 00
b 0H
b 50
( )
( )
( )
b 20
Restore
factory
values
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
µ
Setup Menu
Press > and < for
3 seconds to enter the
Setup Menu.
Range low 1
Input 1
Range high 1
RTD calibration curve
Decimal
(Setup)
Lock
LOC
rL1
rH1
rtd
dEC
In1
rSP
rH2
C_F
rL2
( )
( )
( )
( )
( )
( )
( )
( )
( )
( )
Range high 2
Range low 2
C or F
Remote set point
Output 1
Output 2
Alarm type
Latching
Silencing
Ot1
Ot2
LAt
ALt
SIL
( )
( )
( )
( )
( )
75 50 °F0
% OUT LED onDEV LED on Process units
Set point
or Remote
set point