Series 146
Series 146
Line
Voltage Input Temp Range
Control
Mode
Action
Output Set Point Mounting Retrofit control
See Notes
Below
146E-2101-4000 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Auto Reset
8A Relay Integral DIN Rail LV E6RZ -073 0600 A 6, 8
146E-2101-4000 230 VAC 100 ohm DIN -100 to 1112°F Low Limit
Auto Reset
8A Relay Integral DIN Rail LV E6PZ -100 1112 A 6, 8
146E-2101-4N00 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RZ -073 0600 A 2, 6, 8
146E-2101-4N00 230 VAC 100 ohm DIN -100 to 1112°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PZ -100 1112 A 2, 6, 8
146E-2101-4P00 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RZ -073 0600 A 2, 6, 8
146E-2101-4P00 230 VAC 100 ohm DIN -100 to 1112°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PZ -100 1112 A 2, 6, 8
146E-2101-4S00 230 VAC 100 ohm DIN -73 to 600°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RZ -073 0600 A 2, 6, 8
146E-2101-4S00 230 VAC 100 ohm DIN -100 to 1112°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PZ -100 1112 A 2, 6, 8
146E-2104-1000 230 VAC 1K ohm -73 to 600°C High Limit
Manual Reset
8A Relay Integral DIN Rail LV E6RU -073 0600 A 1, 6, 8
146E-2104-1000 230 VAC 1K ohm -100 to 1112°F High Limit
Manual Reset
8A Relay Integral DIN Rail LV E6PU -100 1112 A 1, 6, 8
146E-2104-1N00 230 VAC 1K ohm -73 to 600°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RU -073 0600 A 1, 2, 6, 8
146E-2104-1N00 230 VAC 1K ohm -100 to 1112°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PU -100 1112 A 1, 2, 6, 8
146E-2104-1P00 230 VAC 1K ohm -73 to 600°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RU -073 0600 A 1, 2, 6, 8
146E-2104-1P00 230 VAC 1K ohm -100 to 1112°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PU -100 1112 A 1, 2, 6, 8
146E-2104-1S00 230 VAC 1K ohm -73 to 600°C High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RU -073 0600 A 1, 2, 6, 8
146E-2104-1S00 230 VAC 1K ohm -100 to 1112°F High Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PU -100 1112 A 1, 2, 6, 8
146E-2104-2000 230 VAC 1K ohm -73 to 600°C Low Limit
Manual Reset
8A Relay Integral DIN Rail LV E6RY -073 0600 A 1, 6, 8
146E-2104-2000 230 VAC 1K ohm -100 to 1112°F Low Limit
Manual Reset
8A Relay Integral DIN Rail LV E6PY -100 1112 A 1, 6, 8
146E-2104-2N00 230 VAC 1K ohm -73 to 600°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RY -073 0600 A 1, 2, 6, 8
146E-2104-2N00 230 VAC 1K ohm -100 to 1112°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PY -100 1112 A 1, 2, 6, 8
146E-2104-2P00 230 VAC 1K ohm -73 to 600°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RY -073 0600 A 1, 2, 6, 8
146E-2104-2P00 230 VAC 1K ohm -100 to 1112°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PY -100 1112 A 1, 2, 6, 8
146E-2104-2S00 230 VAC 1K ohm -73 to 600°C Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5RY -073 0600 A 1, 2, 6, 8
146E-2104-2S00 230 VAC 1K ohm -100 to 1112°F Low Limit
Manual Reset
8A Relay Remote DIN Rail LV E5PY -100 1112 A 1, 2, 6, 8
146E-2104-3000 230 VAC 1K ohm -73 to 600°C High Limit
Auto Reset
8A Relay Integral DIN Rail LV E6RW -073 0600 A 1, 6, 8
146E-2104-3000 230 VAC 1K ohm -100 to 1112°F High Limit
Auto Reset
8A Relay Integral DIN Rail LV E6PW -100 1112 A 1, 6, 8
146E-2104-3N00 230 VAC 1K ohm -73 to 600°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RW -073 0600 A 1, 2, 6, 8
146E-2104-3N00 230 VAC 1K ohm -100 to 1112°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PW -100 1112 A 1, 2, 6, 8
146E-2104-3P00 230 VAC 1K ohm -73 to 600°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RW -073 0600 A 1, 2, 6, 8
146E-2104-3P00 230 VAC 1K ohm -100 to 1112°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PW -100 1112 A 1, 2, 6, 8
146E-2104-3S00 230 VAC 1K ohm -73 to 600°C High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RW -073 0600 A 1, 2, 6, 8
146E-2104-3S00 230 VAC 1K ohm -100 to 1112°F High Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PW -100 1112 A 1, 2, 6, 8
146E-2104-4000 230 VAC 1K ohm -73 to 600°C Low Limit
Auto Reset
8A Relay Integral DIN Rail LV E6RZ -073 0600 A 1, 6, 8
146E-2104-4000 230 VAC 1K ohm -100 to 1112°F Low Limit
Auto Reset
8A Relay Integral DIN Rail LV E6PZ -100 1112 A 1, 6, 8
146E-2104-4N00 230 VAC 1K ohm -73 to 600°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RZ -073 0600 A 1, 2, 6, 8
146E-2104-4N00 230 VAC 1K ohm -100 to 1112°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PZ -100 1112 A 1, 2, 6, 8
146E-2104-4P00 230 VAC 1K ohm -73 to 600°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RZ -073 0600 A 1, 2, 6, 8
146E-2104-4P00 230 VAC 1K ohm -100 to 1112°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PZ -100 1112 A 1, 2, 6, 8
146E-2104-4S00 230 VAC 1K ohm -73 to 600°C Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5RZ -073 0600 A 1, 2, 6, 8
146E-2104-4S00 230 VAC 1K ohm -100 to 1112°F Low Limit
Auto Reset
8A Relay Remote DIN Rail LV E5PZ -100 1112 A 1, 2, 6, 8
146E-2105-1000 230 VAC 100 ohm DIN 0 to 80°C High Limit
Manual Reset
8A Relay Integral DIN Rail LV E6RU 0000 0080 A 6, 8