Watlow Series 146 Retrofit Manual de usuario Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 118
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
Series 146
Series 146
Line
Voltage Input Temp Range
Control
Mode
Action
Output Set Point Mounting Retrofit control
See Notes
Below
146D-3J3D-2200 24 VAC J t/c 149 to 427°C Low Limit
Manual Reset
3A Relay Remote DIN Rail LV G5JY 0149 0427 A
2, 6, 8
146D-3J3D-3100 24 VAC J t/c 300 to 800°F High Limit
Auto Reset
3A Relay Integral DIN Rail LV G6HW 0300 0800 A
6, 8
146D-3J3D-3100 24 VAC J t/c 149 to 427°C High Limit
Auto Reset
3A Relay Integral DIN Rail LV G6JW 0149 0427 A
6, 8
146D-3J3D-3200 24 VAC J t/c 300 to 800°F High Limit
Auto Reset
3A Relay Remote DIN Rail LV G5HW 0300 0800 A
2, 6, 8
146D-3J3D-3200 24 VAC J t/c 149 to 427°C High Limit
Auto Reset
3A Relay Remote DIN Rail LV G5JW 0149 0427 A
2, 6, 8
146D-3J3D-4100 24 VAC J t/c 300 to 800°F Low Limit
Auto Reset
3A Relay Integral DIN Rail LV G6HZ 0300 0800 A
6, 8
146D-3J3D-4100 24 VAC J t/c 149 to 427°C Low Limit
Auto Reset
3A Relay Integral DIN Rail LV G6JZ 0149 0427 A
6, 8
146D-3J3D-4200 24 VAC J t/c 300 to 800°F Low Limit
Auto Reset
3A Relay Remote DIN Rail LV G5HZ 0300 0800 A
2, 6, 8
146D-3J3D-4200 24 VAC J t/c 149 to 427°C Low Limit
Auto Reset
3A Relay Remote DIN Rail LV G5JZ 0149 0427 A
2, 6, 8
146D-3J3F-1100 24 VAC J t/c 300 to 800°F High Limit
Manual Reset
3A Relay Integral DIN Rail LV G6HU 0300 0800 A
6
146D-3J3F-1200 24 VAC J t/c 300 to 800°F High Limit
Manual Reset
3A Relay Remote DIN Rail LV G5HU 0300 0800 A
2, 6
146D-3J3F-2100 24 VAC J t/c 300 to 800°F Low Limit
Manual Reset
3A Relay Integral DIN Rail LV G6HY 0300 0800 A
6
146D-3J3F-2200 24 VAC J t/c 300 to 800°F Low Limit
Manual Reset
3A Relay Remote DIN Rail LV G5HY 0300 0800 A
2, 6
146D-3J3F-3100 24 VAC J t/c 300 to 800°F High Limit
Auto Reset
3A Relay Integral DIN Rail LV G6HW 0300 0800 A
6
146D-3J3F-3200 24 VAC J t/c 300 to 800°F High Limit
Auto Reset
3A Relay Remote DIN Rail LV G5HW 0300 0800 A
2, 6
146D-3J3F-4100 24 VAC J t/c 300 to 800°F Low Limit
Auto Reset
3A Relay Integral DIN Rail LV G6HZ 0300 0800 A
6
146D-3J3F-4200 24 VAC J t/c 300 to 800°F Low Limit
Auto Reset
3A Relay Remote DIN Rail LV G5HZ 0300 0800 A
2, 6
146D-3J4C-1100 24 VAC J t/c -18 to 93°C High Limit
Manual Reset
3A Relay Integral DIN Rail LV G6JU -018 0093 A
6
146D-3J4C-1200 24 VAC J t/c -18 to 93°C High Limit
Manual Reset
3A Relay Remote DIN Rail LV G5JU -018 0093 A
2, 6
146D-3J4C-2100 24 VAC J t/c -18 to 93°C Low Limit
Manual Reset
3A Relay Integral DIN Rail LV G6JY -018 0093 A
6
146D-3J4C-2200 24 VAC J t/c -18 to 93°C Low Limit
Manual Reset
3A Relay Remote DIN Rail LV G5JY -018 0093 A
2, 6
146D-3J4C-3100 24 VAC J t/c -18 to 93°C High Limit
Auto Reset
3A Relay Integral DIN Rail LV G6JW -018 0093 A
6
146D-3J4C-3200 24 VAC J t/c -18 to 93°C High Limit
Auto Reset
3A Relay Remote DIN Rail LV G5JW -018 0093 A
2, 6
146D-3J4C-4100 24 VAC J t/c -18 to 93°C Low Limit
Auto Reset
3A Relay Integral DIN Rail LV G6JZ -018 0093 A
6
146D-3J4C-4200 24 VAC J t/c -18 to 93°C Low Limit
Auto Reset
3A Relay Remote DIN Rail LV G5JZ -018 0093 A
2, 6
146D-3J4D-1100 24 VAC J t/c 0 to 200°F High Limit
Manual Reset
3A Relay Integral DIN Rail LV G6HU 0000 0200 A
6, 8
146D-3J4D-1100 24 VAC J t/c -18 to 93°C High Limit
Manual Reset
3A Relay Integral DIN Rail LV G6JU -018 0093 A
6, 8
146D-3J4D-1200 24 VAC J t/c 0 to 200°F High Limit
Manual Reset
3A Relay Remote DIN Rail LV G5HU 0000 0200 A
2, 6, 8
146D-3J4D-1200 24 VAC J t/c -18 to 93°C High Limit
Manual Reset
3A Relay Remote DIN Rail LV G5JU -018 0093 A
2, 6, 8
146D-3J4D-2100 24 VAC J t/c 0 to 200°F Low Limit
Manual Reset
3A Relay Integral DIN Rail LV G6HY 0000 0200 A
6, 8
146D-3J4D-2100 24 VAC J t/c -18 to 93°C Low Limit
Manual Reset
3A Relay Integral DIN Rail LV G6JY -018 0093 A
6, 8
146D-3J4D-2200 24 VAC J t/c 0 to 200°F Low Limit
Manual Reset
3A Relay Remote DIN Rail LV G5HY 0000 0200 A
2, 6, 8
146D-3J4D-2200 24 VAC J t/c -18 to 93°C Low Limit
Manual Reset
3A Relay Remote DIN Rail LV G5JY -018 0093 A
2, 6, 8
146D-3J4D-3100 24 VAC J t/c 0 to 200°F High Limit
Auto Reset
3A Relay Integral DIN Rail LV G6HW 0000 0200 A
6, 8
146D-3J4D-3100 24 VAC J t/c -18 to 93°C High Limit
Auto Reset
3A Relay Integral DIN Rail LV G6JW -018 0093 A
6, 8
146D-3J4D-3200 24 VAC J t/c 0 to 200°F High Limit
Auto Reset
3A Relay Remote DIN Rail LV G5HW 0000 0200 A
2, 6, 8
146D-3J4D-3200 24 VAC J t/c -18 to 93°C High Limit
Auto Reset
3A Relay Remote DIN Rail LV G5JW -018 0093 A
2, 6, 8
146D-3J4D-4100 24 VAC J t/c 0 to 200°F Low Limit
Auto Reset
3A Relay Integral DIN Rail LV G6HZ 0000 0200 A
6, 8
146D-3J4D-4100 24 VAC J t/c -18 to 93°C Low Limit
Auto Reset
3A Relay Integral DIN Rail LV G6JZ -018 0093 A
6, 8
146D-3J4D-4200 24 VAC J t/c 0 to 200°F Low Limit
Auto Reset
3A Relay Remote DIN Rail LV G5HZ 0000 0200 A
2, 6, 8
146D-3J4D-4200 24 VAC J t/c -18 to 93°C Low Limit
Auto Reset
3A Relay Remote DIN Rail LV G5JZ -018 0093 A
2, 6, 8
Watlow Controls 3/30/2005 Page 24
Vista de pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 117 118

Comentarios a estos manuales

Sin comentarios