0600-0074-0000 Rev. E Made in the U.S.A.December 2013 User’s GuideRegistered Company Winona, Minnesota USA ISO 9001TOTAL3 Year WarrantyCUSTOMERSATIS
Watlow EZ-ZONE® RMH Module • 7 • Chapter 1 Overviewdard Bus to successfully communicate; disconnect all Modbus devices from the network. Once don
Watlow EZ-ZONE® RMH Module • 97 • Chapter 5 Factory Page RM High Density Module • Factory PageDisplayParameter NameDescriptionRange DefaultModb
Watlow EZ-ZONE® RMH Module • 98 • Chapter 5 Factory Page RM High Density Module • Factory PageDisplayParameter NameDescriptionRange DefaultModb
Watlow EZ-ZONE® RMH Module • 99 • Chapter 6 Features6Chapter 6: FeaturesSaving and Restoring User Settings ...101Inputs ...
Watlow EZ-ZONE® RMH Module • 100 • Chapter 6 FeaturesGlobal Function ...126Logic Function ...
Watlow EZ-ZONE® RMH Module • 101 • Chapter 6 FeaturesSaving and Restoring User SettingsRecording setup and operations parameter settings for futur
Watlow EZ-ZONE® RMH Module • 102 • Chapter 6 FeaturesCalibration Menu) for this input to the offset val-ue.5. Check the Electrical Measurement to
Watlow EZ-ZONE® RMH Module • 103 • Chapter 6 FeaturesSelect the low and high values with Range Low [`r;Lo] and Range High [`r;hi] (Setup Page, Ana
Watlow EZ-ZONE® RMH Module • 104 • Chapter 6 FeaturesRetransmitRetransmit SourceOutput ScaleRange HighRange LowScale HighScale LowControl MethodsO
Watlow EZ-ZONE® RMH Module • 105 • Chapter 6 FeaturesOn-off control switches the output either full on or full off, depending on the input, set po
Watlow EZ-ZONE® RMH Module • 106 • Chapter 6 FeaturesTimeTemperaturePID ControlSet PointReduced OvershootProportional BandProportional Band x 2Hea
Watlow EZ-ZONE® RMH Module • 8 • Chapter 1 OverviewRMHControllerRMCControllerRMCControllerRMHControllerRMAccessPowerSupplySlot CSlot CSlot CSlot
Watlow EZ-ZONE® RMH Module • 107 • Chapter 6 Features50 percent output3 ON, 3 OFF66 percent output6 ON, 3 OFFSingle Set Point RampingRamping prote
Watlow EZ-ZONE® RMH Module • 108 • Chapter 6 FeaturesNormal Operating RangeLow Side Alarm RangeHigh Side Alarm RangeAlarm High Set PointAlarm Low
Watlow EZ-ZONE® RMH Module • 109 • Chapter 6 Featurestory Page):• Lock Operations Page [LoC;o] sets the security level for the Operations Page.
Watlow EZ-ZONE® RMH Module • 110 • Chapter 6 Featuresto get to the [`loC] menu. Again push the Advance‰ key until the Password Enabled [pas;e] pro
Watlow EZ-ZONE® RMH Module • 111 • Chapter 6 Features to) the Modbus address of a parameter within the controller. Assembly Working Addres
Watlow EZ-ZONE® RMH Module • 112 • Chapter 6 Featuresdefine the communications port on the PC to use.The available options allow the user to selec
Watlow EZ-ZONE® RMH Module • 113 • Chapter 6 Featureslighted (address 6) to bring greater clarity to the con-trol in focus. Any EZ-ZONE device on
Watlow EZ-ZONE® RMH Module • 114 • Chapter 6 FeaturesAlthough the RMH control now contains the configu-ration (because the previous discussion foc
Watlow EZ-ZONE® RMH Module • 115 • Chapter 6 FeaturesFunction Block DescriptionsEach of the next several pages graphically shows each of the RMH f
Watlow EZ-ZONE® RMH Module • 116 • Chapter 6 FeaturesProcess Value FunctionThe Process Value (PV) function block accepts multiple in-puts and perf
Watlow EZ-ZONE® RMH Module • 9 • Chapter 1 OverviewGetting Started QuicklyConsider taking the following steps to quickly com-mission your control
Watlow EZ-ZONE® RMH Module • 117 • Chapter 6 FeaturesProcess ValueOffProcess ValueSensor BackupProcess ValueAverageProcess ValueCrossoverOutput Va
Watlow EZ-ZONE® RMH Module • 118 • Chapter 6 FeaturesProcess ValueWet Bulb/Dry BulbProcess ValueSwitch OverProcess ValueRatio Output Value = If di
Watlow EZ-ZONE® RMH Module • 119 • Chapter 6 FeaturesProcess ValueAddProcess ValueMultiplyProcess ValueAbsolute DifferenceProcess ValueMinimumOutp
Watlow EZ-ZONE® RMH Module • 120 • Chapter 6 FeaturesProcess ValueMaximumProcess ValueSquare RootProcess ValueVaisala RH CompensationProcess Value
Watlow EZ-ZONE® RMH Module • 121 • Chapter 6 FeaturesLinearization FunctionAn error, when read, can indicate any of the following: None, Open, Sho
Watlow EZ-ZONE® RMH Module • 122 • Chapter 6 FeaturesOutputOutputOutput Low Power ScaleOutput Time BaseOutput ControlOutput High Power ScaleOutput
Watlow EZ-ZONE® RMH Module • 123 • Chapter 6 FeaturesAlarm Alarm Latching Alarm Blocking Alarm SilencingAlarm HysteresisAlarm Clear RequestAlarm S
Watlow EZ-ZONE® RMH Module • 124 • Chapter 6 FeaturesDigital Input/Output Function (cont.) Output Value is determined by Source A and Digital Out-
Watlow EZ-ZONE® RMH Module • 125 • Chapter 6 FeaturesControl FunctionOverviewInstances - 1 - 16 per RMHControl ModeRemote Set Point EnableRemote S
Watlow EZ-ZONE® RMH Module • 126 • Chapter 6 FeaturesGlobal FunctionGlobalOverviewInstances - 1 per RMH[AC;Lf] AC Line Frequency : 50 Hz, 60 Hz[d;
Watlow EZ-ZONE® RMH Module • 10 • Chapter 1 OverviewEZ-ZONE RMH Module - System Diagram16 Control Loops - Slots A, B, D and ER M H x - [1,2] [1,2]
Watlow EZ-ZONE® RMH Module • 127 • Chapter 6 Features LogicANDA * B C D E F G H = ON* * * * * * ErrorSource DValue Source FValue Sour
Watlow EZ-ZONE® RMH Module • 128 • Chapter 6 FeaturesLogicNot EqualIf A = B C D E F G H then ON= = = = = = ErrorSource DValue Source
Watlow EZ-ZONE® RMH Module • 129 • Chapter 6 FeaturesLogicOffOutput Value = OffErrorSource DValue Source FValue Source EValue Source HValue Ou
Watlow EZ-ZONE® RMH Module • 130 • Chapter 6 FeaturesMathOffRange LowRange HighPressure UnitsAltitude UnitsScale LowScale HighFunctionFilter Offse
Watlow EZ-ZONE® RMH Module • 131 • Chapter 6 FeaturesMathDifferentialRange LowRange HighPressure UnitsAltitude UnitsScale LowScale HighFunctionFil
Watlow EZ-ZONE® RMH Module • 132 • Chapter 6 FeaturesMathMultiplyRange LowRange HighPressure UnitsAltitude UnitsScale LowScale HighFunctionFilter
Watlow EZ-ZONE® RMH Module • 133 • Chapter 6 FeaturesMathSquare RootRange LowRange HighPressure UnitsAltitude UnitsScale LowScale HighFunctionFilt
Watlow EZ-ZONE® RMH Module • 134 • Chapter 6 FeaturesTimer Function[SFn;A] Source Function A (Timer Run) : None, Alarm, Compare, Counter, Digital
Watlow EZ-ZONE® RMH Module • 135 • Chapter 6 FeaturesTimerOn PulseFunctionSource Active State ASource Active State BSource Function ASource Instan
Watlow EZ-ZONE® RMH Module • 136 • Chapter 6 FeaturesTimerDelayFunctionSource Active State ASource Active State BSource Function ASource Instance
Watlow EZ-ZONE® RMH Module • 11 • Chapter 1 OverviewEZ-ZONE RMH Module - System Diagram8 Control Loops - Slots A, B 4 - Form A Mechanical Relays -
Watlow EZ-ZONE® RMH Module • 137 • Chapter 6 FeaturesTimerOne ShotFunctionSource Active State ASource Active State BSource Function ASource Instan
Watlow EZ-ZONE® RMH Module • 138 • Chapter 6 FeaturesTimerRetentiveFunctionSource Active State ASource Active State BSource Function ASource Insta
Watlow EZ-ZONE® RMH Module • 139 • Chapter 6 FeaturesCounter FunctionFunction counts up or down from Load Value and produces Output Value = On whe
Watlow EZ-ZONE® RMH Module • 140 • Chapter 6 FeaturesCompare Function[SFn;A] Source Function A : Power, Power, Linearization, Math, Process Value,
Watlow EZ-ZONE® RMH Module • 141 • Chapter 6 FeaturesA not equal B, Output Value = ONToleranceError HandlingFunctionOutput ValueErrorSource AValu
Watlow EZ-ZONE® RMH Module • 142 • Chapter 6 FeaturesDiagnostic FunctionDiagnosticsOverviewInstances - 1 per RMH[rEu] Software Revision: 4.00, ...
Watlow EZ-ZONE® RMH Module • 143 • Appendix7Chapter 10: AppendixModbus - Programmable Memory BlocksThe Modbus assembly contains 40 pointers to the
Watlow EZ-ZONE® RMH Module • 144 • AppendixAssembly Pointer Registers and Assembly Working RegistersDefinition Addresses Working Addresses Definit
Watlow EZ-ZONE® RMH Module • 145 • AppendixModbus Default Assembly Structure 40-119Pointer 1 = 0 & 1Hardware IDRegisters 40 & 41Registers
Watlow EZ-ZONE® RMH Module • 146 • AppendixModbus Default Assembly Structure 120-199Pointer 41 = 0 & 1Hardware IDRegisters 120 & 121Regist
Watlow EZ-ZONE® RMH Module • 12 • Chapter 1 OverviewEZ-ZONE RMH Module - System Diagram8 Control Loops - Slots A, B 6 - Digital I/O - Slot D4 - Fo
Watlow EZ-ZONE® RMH Module • 147 • AppendixTroubleshooting Alarms, Errors and Module IssuesIndication Description Possible Cause(s) Corrective Act
Watlow EZ-ZONE® RMH Module • 148 • AppendixIndication Description Possible Cause(s) Corrective ActionNo Display No display indication or LED illum
Watlow EZ-ZONE® RMH Module • 149 • AppendixIndication Description Possible Cause(s) Corrective ActionRUI value to high[ual;h] Value to high to be
Watlow EZ-ZONE® RMH Module • 150 • AppendixRMH SpecificationsLine Voltage/Power• 20.4 to 30.8Vı (ac/dc), 50/60Hz, ±5 percent• Power consumption:
Watlow EZ-ZONE® RMH Module • 151 • AppendixInput TypeMax Error @ 25 Deg CAccuracy Range LowAccuracy Range HighUnitsmA ac ±5 0 50mAmps ACPotentiome
Watlow EZ-ZONE® RMH Module • 152 • AppendixControl Loops 16 totalCompare 24 total Off, greater than, less than, equal, not equal, greater than
Watlow EZ-ZONE® RMH Module • 153 • AppendixEZ-ZONERail MountEnhancedOptionsFutureOptionsSlot ESlot DSlot BSlot AConnectorStyle/CustomProductHighDe
Watlow EZ-ZONE® RMH Module • 154 • AppendixIndex[`A;bL] Alarm Blocking 70, 109[AC;LF] AC Line Frequency 93[A;Clr] Alarm Clear Request 70[`ACt]
Watlow EZ-ZONE® RMH Module • 155 • AppendixalarmsBlocking 70, 109deviation 108Display 70Hysteresis 69, 108Latching 69, 108Logic 69process 1
Watlow EZ-ZONE® RMH Module • 156 • AppendixLock Proling Page 109Logic 69Logic Function 126Logic Menu 46, 79Loop Menu 40Low Power Scale 58,
Watlow EZ-ZONE® RMH Module • 13 • Chapter 1 OverviewEZ-ZONE RMH Module - System Diagram8 Control Loops - Slots A, B 6 - Digital I/O - Slot D6 - Di
Watlow EZ-ZONE® RMH Module • 157 • AppendixDeclaration of Conformity CE DOC EZ-ZONE RM-09-13 Page 1 of 1 EZ Zone Series RM WATLOW
Watlow EZ-ZONE® RMH Module • 158 • AppendixHow to Reach UsCorporate HeadquartersWatlow Electric Manufacturing Company12001 Lackland RoadSt. Louis,
Watlow EZ-ZONE® RMH Module • 14 • Chapter 1 OverviewEZ-ZONE RMH Module - System Diagram8 Control Loops - Slots A, B 3 - Process Outputs - Slot D o
Watlow EZ-ZONE® RMH Module • 15 • Chapter 2 Install and Wire Chapter 2: Install and Wire2DimensionsModule Removal Clearance Straight ConnectorsMo
Watlow EZ-ZONE® RMH Module • 16 • Chapter 2 Install and Wire (2.03 in)51.56 mm(.66 in)16.76 mm(2.31 in)58.67 mm(.69 in)17.53 mm(2.38 in)60.45 mm(1
Safety Information We use note, caution and warning symbols throughout this book to draw your attention to important operational and safety informati
Watlow EZ-ZONE® RMH Module • 17 • Chapter 2 Install and Wire Power SuppliesDSP30+ +--L NDC LODC OK123 45 653.00 mmDSP302.087 in91.00 mm3.583 in14.
Watlow EZ-ZONE® RMH Module • 18 • Chapter 2 Install and Wire RMH Installation and Removal on a DIN RailModular Backplane ConnectorThe picture on t
Watlow EZ-ZONE® RMH Module • 19 • Chapter 2 Install and Wire Removal of the Modular Back-plane ConnectorA module can be removed from the Modular B
Watlow EZ-ZONE® RMH Module • 20 • Chapter 2 Install and Wire High Density Module (R M H x - x x x x - x x x x)Slot A Slot B Slot D Slot E Configur
Watlow EZ-ZONE® RMH Module • 21 • Chapter 2 Install and Wire High Density Module (R M H x - x x x x - x x x x)Slot A Slot B Slot D Slot E Configur
Watlow EZ-ZONE® RMH Module • 22 • Chapter 2 Install and Wire Slot ASlot ESlot DSlot B RMH Module - Front View -Standard Connector9899Slot Cpow
Watlow EZ-ZONE® RMH Module • 23 • Chapter 2 Install and Wire Digital Inputs & Outputs,Process OutputsAnalog Input 1 - 16Communications PortsCo
Warning: çUse National Electric (NEC) or other country-specific standard wiring and safety practices when wiring and connecting this controller to a
Watlow EZ-ZONE® RMH Module • 25 • Chapter 2 Install and Wire Warning: çUse National Electric (NEC) or other country-specific standard wiring and
Warning: çUse National Electric (NEC) or other country-specific standard wiring and safety practices when wiring and connecting this controller to a
returning any product for credit, repair or evaluation. Make sure the Return Merchandise Authorization number is on the outside of the carton and on a
Watlow EZ-ZONE® RMH Module • 27 • Chapter 2 Install and Wire Warning: çUse National Electric (NEC) or other country-specific standard wiring and
Warning: çUse National Electric (NEC) or other country-specific standard wiring and safety practices when wiring and connecting this controller to a
Watlow EZ-ZONE® RMH Module • 29 • Chapter 2 Install and Wire Warning: çUse National Electric (NEC) or other country-specific standard wiring and
Warning: çUse National Electric (NEC) or other country-specific standard wiring and safety practices when wiring and connecting this controller to a
Watlow EZ-ZONE® RMH Module • 31 • Chapter 2 Install and Wire Warning: çUse National Electric (NEC) or other country-specific standard wiring and
Warning: çUse National Electric (NEC) or other country-specific standard wiring and safety practices when wiring and connecting this controller to a
Watlow EZ-ZONE® RMH Module • 33 • Chapter 2 Install and Wire 9899CFCDCEB5D6D5- A+ Bco m m onPowerSupply- A+ BcommonRUI/GatewayEZ-ZONE® PMfuseEZ-ZO
Watlow EZ-ZONE® RMH Module • 34 • Chapter 2 Install and Wire Connecting and Wiring the ModulesRMH Module ConnectionsThe RMH module can be installe
Watlow EZ-ZONE® RMH Module • 35 • Chapter 2 Menu ConventionsConventions Used in the Menu PagesTo better understand the menu pages that follow revi
Watlow EZ-ZONE® RMH Module • 36 • Chapter 2 Menu Conventionsthe header as Modbus and notice that it lists register 380. Because this parameter is
Watlow EZ-ZONE® RMH Module • 1 • Table of ContentsTCTable of ContentsChapter 1: Overview ...3A Conceptual View
Watlow EZ-ZONE® RMH Module • 37 • Chapter 3 Operations PageChapter 3: Operations Pages3[``Ai][oPEr] Analog Input Menu [```1] [``Ai] Analog Input (
Watlow EZ-ZONE® RMH Module • 38 • Chapter 3 Operations Page[`LgC][oPEr] Logic Menu [```1] [`LgC] Logic (1 to 24) [`Su;A] Source Value A [`Su;b
Watlow EZ-ZONE® RMH Module • 39 • Chapter 3 Operations Page RM High Density Module • Operations PageDisplayParameter NameDescriptionRange Defau
Watlow EZ-ZONE® RMH Module • 40 • Chapter 3 Operations Page RM High Density Module • Operations PageDisplayParameter NameDescriptionRange Defau
Watlow EZ-ZONE® RMH Module • 41 • Chapter 3 Operations Page RM High Density Module • Operations PageDisplayParameter NameDescriptionRange Defau
Watlow EZ-ZONE® RMH Module • 42 • Chapter 3 Operations Page RM High Density Module • Operations PageDisplayParameter NameDescriptionRange Defau
Watlow EZ-ZONE® RMH Module • 43 • Chapter 3 Operations Page RM High Density Module • Operations PageDisplayParameter NameDescriptionRange Defau
Watlow EZ-ZONE® RMH Module • 44 • Chapter 3 Operations Page RM High Density Module • Operations PageDisplayParameter NameDescriptionRange Defau
Watlow EZ-ZONE® RMH Module • 45 • Chapter 3 Operations Page RM High Density Module • Operations PageDisplayParameter NameDescriptionRange Defau
Watlow EZ-ZONE® RMH Module • 46 • Chapter 3 Operations Page RM High Density Module • Operations PageDisplayParameter NameDescriptionRange Defau
Watlow EZ-ZONE® RMH Module • 2 • Table of ContentsLogic Menu ...79Math Menu ...
Watlow EZ-ZONE® RMH Module • 47 • Chapter 3 Operations Page RM High Density Module • Operations PageDisplayParameter NameDescriptionRange Defau
Watlow EZ-ZONE® RMH Module • 48 • Chapter 3 Operations Page RM High Density Module • Operations PageDisplayParameter NameDescriptionRange Defau
Watlow EZ-ZONE® RMH Module • 49 • Chapter 4 Setup PageChapter 4: Setup Pages4[``Ai][`Set] Analog Input Menu [```1] [``Ai] Analog Input (1 to 16)
Watlow EZ-ZONE® RMH Module • 50 • Chapter 4 Setup Page [`L;dE] Open Loop Detect Enable [`L;dt] Open Loop Detect Time [`L;dd] Open Loop Detec
Watlow EZ-ZONE® RMH Module • 51 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 52 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 53 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 54 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 55 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 56 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 3 • Chapter 1 OverviewChapter 1: Overview 1Available EZ-ZONE RM System Literature and ResourcesDocument Title and Pa
Watlow EZ-ZONE® RMH Module • 57 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 58 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 59 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 60 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 61 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 62 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 63 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 64 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 65 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 66 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 4 • Chapter 1 OverviewIntroductionThe EZ-ZONE® RM High Density (RMH) control module provides multi-loop (4 to 16 loo
Watlow EZ-ZONE® RMH Module • 67 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 68 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 69 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 70 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 71 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 72 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 73 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 74 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 75 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 76 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 5 • Chapter 1 OverviewControl capability• Allows individual modules to be mounted closer to the physical input and
Watlow EZ-ZONE® RMH Module • 77 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 78 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 79 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 80 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 81 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 82 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 83 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 84 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 85 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 86 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 6 • Chapter 1 OverviewA Conceptual View of the RMHThe flexibility of the RMH’s software and hardware allows for vari
Watlow EZ-ZONE® RMH Module • 87 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 88 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 89 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 90 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 91 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 92 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 93 • Chapter 4 Setup Page RM High Density Module • Setup PageDisplayParameter NameDescriptionRange DefaultModbus R
Watlow EZ-ZONE® RMH Module • 94 • Chapter 5 Factory PageChapter 5: Factory Pages5[CUSt][FCty] Custom Setup Menu [```1] [CUSt] Custom Setup (1 to 5
Watlow EZ-ZONE® RMH Module • 95 • Chapter 5 Factory Page RM High Density Module • Factory PageDisplayParameter NameDescriptionRange DefaultModb
Watlow EZ-ZONE® RMH Module • 96 • Chapter 5 Factory Page RM High Density Module • Factory PageDisplayParameter NameDescriptionRange DefaultModb