PPC-2000 User’s Guide Chapter 2: Hardware Installation
Doc.# 30002-00 Rev 2.3 Watlow Anafaze 57
Table 2.17 Power Connections on EITB
Encoder Wiring
The EITB accommodates four configurations of frequency/
counter inputs:
Single-ended/single phase
Single-ended/quadrature
Differential/single phase
Differential/quadrature
Note that these are four unique inputs and each input has two
phases. Both phases are used only in quadrature mode
nominally.
Figure 2.41 EITB Single-ended Single Phase
Connections: Input 1 and 2 Shown
Voltage EITB Terminals
+5Vdc 1, 7
COM 6, 12
2 (input 1 phase 1+)
8 (input 2 phase 1+)
12 (COM)
S1
+
-
+
-
S2