Appendix B: 8LS-CP
8LS User’s Guide 117
typically used in continuous furnace applications. Setting the start mode
to Input means the burn off procedure will be started based on a digital
input signal. This is typically used in batch furnace applications.
Selectable Values: Off, Time, Input.
Burn Off Time Interval
This menu is displayed if the start mode is set to Time. Use it to edit the
time interval between the burn off function.
Selectable Range: 1-255.
Burn Off start Input
This menu is displayed if the start mode is set to Input. Use it to edit the
digital input number which will initiate the burn off procedure. When
the input is set to 0, the procedure will not start from any digital input
and the burn off function will be deactivated.
Selectable Range: 1-12, or 0.
1234 56 78
LOOP PROCESS UNITS
ALARM
SETPOINT
STATUS
OUTPUT%
2BO STRT
MD? OFF
1234 56 78
LOOP PROCESS UNITS
ALARM
SETPOINT
STATUS
OUTPUT%
2BO INTR
HRS? 3
1234 56 78
LOOP PROCESS UNITS
ALARM
SETPOINT STATUS OUTPUT%
2BO STRT
INPUT? 0