Watlow 8LS Controller Manual de usuario Pagina 124

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 140
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 123
116 8LS Users Guide
Appendix B: 8LS-CP
Offset Calibration
If the carbon probe input type is set to CP or DP, a menu is available for
editing an offset calibration of the probe input in the engineering units
of the process variable.
The MV input is in direct reading of the millivolt output of the carbon
probe with no offset adjustable available.
Selectable Range:
WARNING
Incorrect setting of these values may cause incor-
rect operation of the 8LS-CP.
Setup Carbon Burn Off
Use the following menus to edit the carbon burn off function of the 8LS-
CP.
Burn Off Start Mode
This menu allows you to edit the burn off start mode. Setting it to Off
will deactivate the burn off. Selecting Time means the burn off
procedure will be started periodically based on a time interval. This is
Input
Type
Offset Range
CP -.99 to +9.99% of Carbon
DP -300 to +300
º
F/C
1234 56 78
LOOP PROCESS UNITS
ALARM SETPOINT STATUS OUTPUT%
2 OFFSET
? 0 ºF
1234 56 78
LOOP PROCESS UNITS
ALARM
SETPOINT
STATUS
OUTPUT%
2 CP
BURNOFF?
Vista de pagina 123