Chapter 3: Controller Parameter Descriptions
Communications Specification 61
Default: 0 (no low deviation alarm output).
Channel Profile and Status (46)
In this byte, bits 0 to 4 hold the ramp-soak profile number for the loop.
Bits 5 to 7 hold the profile’s status (Ready, Running, Hold, Trigger Wait,
or Out of Tolerance).
Range: See tables below.
Default: 0.
Bits 0 to 4 hold the profile number and reference letter:
Bits 5, 6, and 7 hold the profile status:
Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Profile
Number
Ref.
Letter
00000 0 A
00001 1 B
00010 2 C
00011 3 D
00100 4 E
00101 5 F
00110 6 G
00111 7 H
01000 8 I
01001 9 J
01010 10 K
01011 11 L
01100 12 M
01101 13 N
01110 14 O
01111 15 P
10000 16 Q
Bit 7 Bit 6 Bit 5 Status
000
Profile in Ready state
“S”
0 0 1 Profile is running “R”
010
Profile is holding
“H”
0 1 1 Profile in trigger wait state “W”
1 0 0 Profile out of tolerance “O”
1 1 1 No profile assigned