Series 142
Series 142
Line
Voltage Input Temp Range Control Mode Action Output Set Point Mounting Retrofit
See Notes
Below
142A-3604-2200 230 VAC J t/c 149°C High limit
Manual Reset
3A Relay Fixed Potted LF E4JU 0149 AAAA A 6, 8
142A-3604-2300 230 VAC J t/c 300°F High limit
Automatic Reset
3A Relay Fixed Potted LF E4HW 0300 AAAA A 6, 8
142A-3604-2300 230 VAC J t/c 149°C High limit
Automatic Reset
3A Relay Fixed Potted LF E4JW 0149 AAAA A 6, 8
142A-3604-2400 230 VAC J t/c 300°F On/Off
Heat
3A Relay Fixed Potted CF E4HH 0300 AAAA A 6, 8
142A-3604-2400 230 VAC J t/c 149°C On/Off
Heat
3A Relay Fixed Potted CF E4JH 0149 AAAA A 6, 8
142A-3605-1200 120 VAC J t/c 325°F High limit
Manual Reset
3A Relay Fixed Potted LF C4HU 0325 AAAA A 6, 8
142A-3605-1200 120 VAC J t/c 163°C High limit
Manual Reset
3A Relay Fixed Potted LF C4JU 0163 AAAA A 6, 8
142A-3605-1300 120 VAC J t/c 325°F High limit
Automatic Reset
3A Relay Fixed Potted LF C4HW 0325 AAAA A 6, 8
142A-3605-1300 120 VAC J t/c 163°C High limit
Automatic Reset
3A Relay Fixed Potted LF C4JW 0163 AAAA A 6, 8
142A-3605-1400 120 VAC J t/c 325°F On/Off
Heat
3A Relay Fixed Potted CF C4HH 0325 AAAA A 6, 8
142A-3605-1400 120 VAC J t/c 163°C On/Off
Heat
3A Relay Fixed Potted CF C4JH 0163 AAAA A 6, 8
142A-3605-2200 230 VAC J t/c 325°F High limit
Manual Reset
3A Relay Fixed Potted LF E4HU 0325 AAAA A 6, 8
142A-3605-2200 230 VAC J t/c 163°C High limit
Manual Reset
3A Relay Fixed Potted LF E4JU 0163 AAAA A 6, 8
142A-3605-2300 230 VAC J t/c 325°F High limit
Automatic Reset
3A Relay Fixed Potted LF E4HW 0325 AAAA A 6, 8
142A-3605-2300 230 VAC J t/c 163°C High limit
Automatic Reset
3A Relay Fixed Potted LF E4JW 0163 AAAA A 6, 8
142A-3605-2400 230 VAC J t/c 325°F On/Off
Heat
3A Relay Fixed Potted CF E4HH 0325 AAAA A 6, 8
142A-3605-2400 230 VAC J t/c 163°C On/Off
Heat
3A Relay Fixed Potted CF E4JH 0163 AAAA A 6, 8
142A-3606-1200 120 VAC J t/c 350°F High limit
Manual Reset
3A Relay Fixed Potted LF C4HU 0350 AAAA A 6, 8
142A-3606-1200 120 VAC J t/c 177°C High limit
Manual Reset
3A Relay Fixed Potted LF C4JU 0177 AAAA A 6, 8
142A-3606-1300 120 VAC J t/c 350°F High limit
Automatic Reset
3A Relay Fixed Potted LF C4HW 0350 AAAA A 6, 8
142A-3606-1300 120 VAC J t/c 177°C High limit
Automatic Reset
3A Relay Fixed Potted LF C4JW 0177 AAAA A 6, 8
142A-3606-1400 120 VAC J t/c 350°F On/Off
Heat
3A Relay Fixed Potted CF C4HH 0350 AAAA A 6, 8
142A-3606-1400 120 VAC J t/c 177°C On/Off
Heat
3A Relay Fixed Potted CF C4JH 0177 AAAA A 6, 8
142A-3606-2200 230 VAC J t/c 350°F High limit
Manual Reset
3A Relay Fixed Potted LF E4HU 0350 AAAA A 6, 8
142A-3606-2200 230 VAC J t/c 177°C High limit
Manual Reset
3A Relay Fixed Potted LF E4JU 0177 AAAA A 6, 8
142A-3606-2300 230 VAC J t/c 350°F High limit
Automatic Reset
3A Relay Fixed Potted LF E4HW 0350 AAAA A 6, 8
142A-3606-2300 230 VAC J t/c 177°C High limit
Automatic Reset
3A Relay Fixed Potted LF E4JW 0177 AAAA A 6, 8
142A-3606-2400 230 VAC J t/c 350°F On/Off
Heat
3A Relay Fixed Potted CF E4HH 0350 AAAA A 6, 8
142A-3606-2400 230 VAC J t/c 177°C On/Off
Heat
3A Relay Fixed Potted CF E4JH 0177 AAAA A 6, 8
142A-3607-1200 120 VAC J t/c 375°F High limit
Manual Reset
3A Relay Fixed Potted LF C4HU 0375 AAAA A 6, 8
142A-3607-1200 120 VAC J t/c 191°C High limit
Manual Reset
3A Relay Fixed Potted LF C4JU 0191 AAAA A 6, 8
142A-3607-1300 120 VAC J t/c 375°F High limit
Automatic Reset
3A Relay Fixed Potted LF C4HW 0375 AAAA A 6, 8
142A-3607-1300 120 VAC J t/c 191°C High limit
Automatic Reset
3A Relay Fixed Potted LF C4JW 0191 AAAA A 6, 8
142A-3607-1400 120 VAC J t/c 375°F On/Off
Heat
3A Relay Fixed Potted CF C4HH 0375 AAAA A 6, 8
142A-3607-1400 120 VAC J t/c 191°C On/Off
Heat
3A Relay Fixed Potted CF C4JH 0191 AAAA A 6, 8
142A-3607-2200 230 VAC J t/c 375°F High limit
Manual Reset
3A Relay Fixed Potted LF E4HU 0375 AAAA A 6, 8
142A-3607-2200 230 VAC J t/c 191°C High limit
Manual Reset
3A Relay Fixed Potted LF E4JU 0191 AAAA A 6, 8
142A-3607-2300 230 VAC J t/c 375°F High limit
Automatic Reset
3A Relay Fixed Potted LF E4HW 0375 AAAA A 6, 8
142A-3607-2300 230 VAC J t/c 191°C High limit
Automatic Reset
3A Relay Fixed Potted LF E4JW 0191 AAAA A 6, 8
142A-3607-2400 230 VAC J t/c 375°F On/Off
Heat
3A Relay Fixed Potted CF E4HH 0375 AAAA A 6, 8
142A-3607-2400 230 VAC J t/c 191°C On/Off
Heat
3A Relay Fixed Potted CF E4JH 0191 AAAA A 6, 8
Watlow Controls 1/31/2005 Page 5